VMS Carbon

Lab tests for activated carbon: ASTM, JIS and BIS methods

Standard activated carbon tests for iodine number, methylene blue, hardness, ash, moisture, density, pH and particle size, and how to compare lab results.

VMS Carbon technical team · 2 min read · Updated 31 October 2026

Lab tests for activated carbon: ASTM, JIS and BIS methods

Activated carbon is bought on test results, so it helps to know which tests exist, what they measure and why the same carbon can show different numbers in different labs.

The main standards

  • ASTM (American) methods are the most widely quoted in international trade.
  • JIS K 1474 (Japanese Industrial Standard) covers a full set of activated carbon tests and is common in Asian trade.
  • BIS (Bureau of Indian Standards) methods are used in India.
  • AWWA B600 and B604 set requirements for powdered and granular carbon in drinking water treatment.
  • CEFIC methods (European chemical industry) are used for some tests.
Iodine numberMethylene blueTest reportIodine numberMethylene blueHardnessAshMoisture

How every lot is tested

  1. A sample is taken from every lot
  2. Iodine number: how much it can adsorb
  3. Methylene blue: how it takes larger molecules
  4. Hardness, ash and moisture go on the report

Common tests

PropertyCommon methodsWhat it tells you
Iodine numberASTM D4607, JIS K 1474micropore adsorption capacity
Methylene blueJIS K 1474, BIS methodsmesopore capacity, colour removal
Ball-pan hardnessASTM D3802resistance to breaking into fines
Total ashASTM D2866mineral content
MoistureASTM D2867water content
Apparent densityASTM D2854weight per volume for bed design
Particle sizeASTM D2862sieve distribution of granules
pHASTM D3838pH of water in contact with carbon
Butane activityASTM D5742vapour capacity (gas phase)

Why numbers differ between labs

  • Different methods. Methylene blue in mg/g and in ml/g are not the same scale; iodine methods differ in detail.
  • Particle size. Many tests grind the sample first; others test it as received.
  • Moisture. Results may be on a dry or as-received basis.
  • Sampling. A small sample from one bag may not represent a lot; proper sampling takes increments from many bags.

A good certificate of analysis

Ask that each lot's certificate states:

  • lot number and production date;
  • each result with its method and basis (dry or as received);
  • the specification limits next to the results;
  • the lab and signatory.

Testing in your own process

Standard tests compare carbons with each other. They do not predict exactly how a carbon performs on your water, oil or gas. For that, run an application test: a jar test for powder, a small column test for granules, a breakthrough test for gas phase.

Every lot we ship has a report for iodine number, methylene blue, hardness, moisture and ash to ASTM, JIS or BIS methods. Ask for a data sheet or a sample.

Frequently asked questions

Which test best predicts colour removal?

Methylene blue or a molasses decolorizing test, both of which reflect mesopores, rather than iodine number.

Can I compare an ASTM iodine number with a JIS one?

Roughly, but not exactly. Ask both suppliers to report by the same method if the numbers are close.

How should a sample be taken from a delivery?

Take small amounts from several bags across the lot and combine them, rather than one scoop from one bag.